Product Description
100KW 3 phase 480 volt input down to USA 240 volt120 volt split phase output converter with outdoor cabinet optional3 phase 480 volt input down to USA 240 volt120 volt split phase output converterAdvantages: 1. Easy to repairAdopted Japanese Mitsubishi IPM intelligent module, Modular and simple structure design, very easy and convenient for maintenance, any fault only need us send you parts for replacement, maintenance is low-skill work 2. Little fault rateIt with powerful protection function for short circuit, over load and over temperature which is more safe and reliable. Fault rate < 1%3. 100% full power stable outputInside with full power low frequency isolated transformer, 100% full power output, can work 24hx7, which ensure the AC busbar and DC busbar are completely isolated, the harmonic and interference is very little, constant voltage and constant frequency stable output. And the accuracy of output voltage is very high less than 1%.4. High efficiency> 92%5. Long service life> 15 years6. Setting flexibleThe output frequency 50Hz/60Hz can be set.The output voltage can be set.7. Two kinds of start modeVariable Frequency Start or Step Down Voltage StartWith higher capacity to drive motor inductive load, save the cost of soft starter8. Big LCD displayDisplay real time running parameters, easy operation120/240V 60Hz Split phase to 380V 50hz 3 phase converterSpecifications: AC InputAC input voltage - 2 Phase 120/240Vac(L1,L2-N 120V. L1-L2 240V)AC OutputAC output power - 3kw-500kw avaliablePure sine wave380VACThree phase L1 + L2 + L3 + N + EarthFrequency 50/60 hzPower Factor: >0.95Inverter efficiency: >94%LCD DisplayVoltage accuracy - Load balancing<1%, Unbalance <5%THD: linear load, 2%, nonlinear load >3%No load amps: 2% of inverter size depending on DC voltage (1000 watts / DC input voltage = amps)ProtectionsOverload 150% for 5 seconds, 120% for 35 secondsInput reverse polarityUnder voltageOver voltageOutput over currentShort circuitOver temperatureFan cooled - Always onShort circuit: no automatic recovery. Restart required<50dBOperating temperature: -25 to 55 CelsiusHumidity: 90% non-condensing
FAQs of 100KW 3 phase 480 volt input down to USA 240 volt120 volt split phase output converter with outdoor cabinet optional:
Q: What is the efficiency level of the 100KW 3 phase 480 volt to USA 240 volt/120 volt split phase converter?
A: The converter has an efficiency level of greater than 94%.
Q: What is the noise level of the 100KW outdoor optional converter during operation?
A: The noise level of the converter is less than 50 dB.
Q: What voltage protection features are included in the converter?
A: The converter is equipped with over-voltage and under-voltage protection.
Q: What are the input and output voltage specifications for the converter?
A: The input voltage is 3 phase 480V, and the output voltage is split phase USA 240V/120V.
Q: What material is used to construct the converter and is an outdoor cabinet optional?
A: The converter is made using steel plates, and an outdoor cabinet is available as an optional feature.