Product Description
20kw 30kw 50kw Danick inverter 400vdc(300-500Vdc) low frequency off grid solar inverterTechnical Features/Our AdvantagesWith low frequency transformer, 100% full power output, can work 24hx7.High efficiency > 94%, low loss and long service life > 15 years.Mitsubishi IPM intelligent modular structure design, easy and low cost for futures maintenance, powerful protection for over load, short circuit, over temperature which is more safe and reliable.The DC input voltge range, output voltage, output frequency can be set.Two kinds of start mode: variable frequency start or step down voltage start, higher capacity to drive inductive load.AC bypass input(DC power priority or AC bypass power priority can be set) and RS485 monitoring optional.Wide voltage input range can be selected from 100-400VDC or 200-600VDC or 400-800VDC, off grid inverter can work without battery.Powerful data display function. LCD can display the DC input voltage, output frequency, phase voltage, phase current, AC bypass input voltage, output power KWH, time and date, temperature, fault code display.Approved by European CE (EMC, LVD, UL1741, CSA22.2) certificate.Optional FunctionRS485 remote monitoringCan add AC bypass input complementary functionCan built in solar charge controller or AC-DC chargerProduct SpecificationsDC InputDC input: 120/144/192/240/300/360/480/540/600VdcAC Bypass Input: OptionalAC OutputRated output power: 30kwPure sine waveAC output voltage: 110/120/220/230/240/380/400/415/440/480VAC (optional)Output phase: Single phase or Split phase or Three phaseFrequency: 50hz or 60hzPower Factor: >0.95Inverter efficiency: >94%LCD DisplayVoltage accuracy: Load balancing<1%, Unbalance <5%THD: linear load, 2%, nonlinear load >3%No load amps: 2% of inverter size depending on DC voltage (1000 watts / DC input voltage = amps)ProtectionsOverload 150% for 5 seconds, 120% for 35 secondsInput reverse polarityUnder voltageOver voltageOutput over currentShort circuitOver temperatureFan cooled, Always onShort circuit: no automatic recovery. Restart required<50dBOperating temperature: -25 to 55 CelsiusHumidity: 90% non-condensingDimensions: 600mm(Width) x 700mm(Depth) x 1150mm(Height)Weight: 270kg
FAQs of 20kw 30kw 50kw Danick inverter 400vdc(300-500Vdc) low frequency off grid solar inverter:
Q: What is the input DC voltage range for the Danick inverter?
A: The input DC voltage range for the Danick inverter is 300-500VDC with a nominal 400VDC.
Q: What are the available rated output voltage options for the inverter?
A: The inverter offers optional rated output voltage options, including 110/120/220/230/240/380/400/415/440/480VAC.
Q: What frequency options are available for this low-frequency off-grid solar inverter?
A: The inverter supports both 50Hz and 60Hz frequency options.
Q: What protection ratings are available for the Danick inverter?
A: The inverter comes with an IP20 protection rating for indoor use and an IP54 protection rating for outdoor use.
Q: What is the standard certification compliance for this inverter?
A: The Danick inverter is certified with CE (EMC & LVD), UL1741, and CSA22.2 standards.