Product Description
300-500vdc input rack mount off grid inverterTechnical Features/Our AdvantagesWith low frequency transformer, 100% full power output, can work 24hx7.High efficiency > 94%, low loss and long service life > 15 years.Mitsubishi IPM intelligent modular structure design, easy and low cost for futures maintenance, powerful protection for over load, short circuit, over temperature which is more safe and reliable.The DC input voltge range, output voltage, output frequency can be set.Two kinds of start mode: variable frequency start or step down voltage start, higher capacity to drive inductive load.AC bypass input(DC power priority or AC bypass power priority can be set) and RS485 monitoring optional.Wide voltage input range can be selected from 100-400VDC or 200-600VDC or 400-800VDC, off grid inverter can work without battery.Powerful data display function. LCD can display the DC input voltage, output frequency, phase voltage, phase current, AC bypass input voltage, output power KWH, time and date, temperature, fault code display.Approved by European CE (EMC, LVD, UL1741, CSA22.2) certificate.Optional FunctionRS485 remote monitoringCan add AC bypass input complementary functionCan built in solar charge controller or AC-DC chargerProduct SpecificationsDC InputDC input: 48/96/120/144/192/240/300/360/480/540/600VdcAC Bypass Input: OptionalAC OutputRated output power: 12kwPure sine waveAC output voltage: 110/120/220/230/240/380/400/415/440/480VAC (optional)Output phase: Single phase or Split phase or Three phaseFrequency: 50hz or 60hzPower Factor: >0.95Inverter efficiency: >94%LCD DisplayVoltage accuracy: Load balancing<1%, Unbalance <5%THD: linear load, 2%, nonlinear load >3%No load amps: 2% of inverter size depending on DC voltage (1000 watts / DC input voltage = amps)ProtectionsOverload 150% for 5 seconds, 120% for 35 secondsInput reverse polarityUnder voltageOver voltageOutput over currentShort circuitOver temperatureFan cooled, Always onShort circuit: no automatic recovery. Restart required<50dBOperating temperature: -25 to 55 CelsiusHumidity: 90% non-condensingDimensions: Rack Mount Cabinet 482mm(Width) x 680mm(Depth) x 300mm(Height) or Stand Cabinet 550mm(Width) x 550mm(Depth) x 860mm(Height)Weight: 130kg
FAQs of 300-500vdc input rack mount off grid inverter:
Q: What is the input voltage range for the 300-500VDC Input Rack Mount Off-Grid Inverter?
A: The input voltage range for this inverter is 300-500VDC.
Q: What type of protections does this inverter offer?
A: This inverter is available with IP20 protection for indoor use and IP54 protection for outdoor installations.
Q: What are the dimensions of the inverter?
A: The dimensions of the inverter are 550*550*860 millimeters (mm).
Q: What are the available output voltage options for this inverter?
A: The inverter provides various output voltage options including 110/120/220/230/240/380/400/415/440/480VAC.
Q: What standards does the 300-500VDC Input Rack Mount Off-Grid Inverter comply with?
A: The inverter complies with CE (EMC & LVD), UL1741, and CSA22.2 standards.
Q: What is the weight of the inverter?
A: The inverter weighs 130 kilograms (kg).
Q: What is the frequency range of operation for this inverter?
A: The inverter operates at a frequency of either 50 or 60 Hertz (Hz).