50KW USA 240 volt input to 3 phase out 480 volt output converter with outdoor cabinet optional240 volt input to 3 phase out 480 volt output converterAdvantages: 1. Easy to repairAdopted Japanese Mitsubishi IPM intelligent module, Modular and simple structure design, very easy and convenient for maintenance, any fault only need us send you parts for replacement, maintenance is low-skill work 2. Little fault rateIt with powerful protection function for short circuit, over load and over temperature which is more safe and reliable. Fault rate < 1%3. 100% full power stable outputInside with full power low frequency isolated transformer, 100% full power output, can work 24hx7, which ensure the AC busbar and DC busbar are completely isolated, the harmonic and interference is very little, constant voltage and constant frequency stable output. And the accuracy of output voltage is very high less than 1%.4. High efficiency> 92%5. Long service life> 15 years6. Setting flexibleThe output frequency 50Hz/60Hz can be set.The output voltage can be set.7. Two kinds of start modeVariable Frequency Start or Step Down Voltage StartWith higher capacity to drive motor inductive load, save the cost of soft starter8. Big LCD displayDisplay real time running parameters, easy operation120/240V 60Hz Split phase to 380V 50hz 3 phase converterSpecifications: AC InputAC input voltage - 2 Phase 120/240Vac(L1,L2-N 120V. L1-L2 240V)AC OutputAC output power - 3kw-500kw avaliablePure sine wave380VACThree phase L1 + L2 + L3 + N + EarthFrequency 50/60 hzPower Factor: >0.95Inverter efficiency: >94%LCD DisplayVoltage accuracy - Load balancing<1%, Unbalance <5%THD: linear load, 2%, nonlinear load >3%No load amps: 2% of inverter size depending on DC voltage (1000 watts / DC input voltage = amps)ProtectionsOverload 150% for 5 seconds, 120% for 35 secondsInput reverse polarityUnder voltageOver voltageOutput over currentShort circuitOver temperatureFan cooled - Always onShort circuit: no automatic recovery. Restart required<50dBOperating temperature: -25 to 55 CelsiusHumidity: 90% non-condensing
FAQs of 50KW USA 240 volt input to 3 phase out 480 volt output converter with outdoor cabinet optional:
Q: What is the input voltage requirement for the 50KW USA 240 Volt input to 3 Phase 480 Volt output converter?
A: The converter requires a 2-phase 240 Volt (V) input.
Q: What type of protection features does this converter offer?
A: The converter includes over/under voltage protection to ensure safe operation.
Q: What is the efficiency rating of the 50KW USA converter?
A: The converter operates with an efficiency of greater than 94%.
Q: What are the operating storage temperature limits for this converter?
A: The storage temperature for the converter ranges from -15 to 50 degrees Celsius (oC).
Q: Does the converter produce significant noise during operation?
A: No, the noise level is less than 50 dB, ensuring quiet operation.
Q: What material is used for the construction of the converters cabinet?
A: The converters cabinet is made from steel plate.
Q: Can this converter be used with an outdoor cabinet?
A: Yes, an outdoor cabinet is optional for this converter.