• danicksolar@gmail.com

50KW USA 240 volt input to 3 phase  out 480 volt output converter with outdoor cabinet  optional
50KW USA 240 volt input to 3 phase  out 480 volt output converter with outdoor cabinet  optional 50KW USA 240 volt input to 3 phase  out 480 volt output converter with outdoor cabinet  optional 50KW USA 240 volt input to 3 phase  out 480 volt output converter with outdoor cabinet  optional 50KW USA 240 volt input to 3 phase  out 480 volt output converter with outdoor cabinet  optional
50KW USA 240 volt input to 3 phase  out 480 volt output converter with outdoor cabinet  optional 50KW USA 240 volt input to 3 phase  out 480 volt output converter with outdoor cabinet  optional 50KW USA 240 volt input to 3 phase  out 480 volt output converter with outdoor cabinet  optional 50KW USA 240 volt input to 3 phase  out 480 volt output converter with outdoor cabinet  optional 50KW USA 240 volt input to 3 phase  out 480 volt output converter with outdoor cabinet  optional

50KW USA 240 volt input to 3 phase out 480 volt output converter with outdoor cabinet optional

10200 USD ($)/Piece

Product Details:

  • Noise Level <50 db
  • Output Type Triple
  • Rated Power 50KW
  • Phase Three Phase
  • Product Type AC-DC-AC Converter
  • Output Power 10000 Watt (w)
  • Output Frequency 50 or 60 Hertz (HZ)
  • Click to View more
X

50KW USA 240 volt input to 3 phase out 480 volt output converter with outdoor cabinet optional Price And Quantity

  • 10200 USD ($)/Piece
  • 1 Piece

50KW USA 240 volt input to 3 phase out 480 volt output converter with outdoor cabinet optional Product Specifications

  • Triple
  • >94%
  • 10000 Watt (w)
  • <50 db
  • -15 ~ 50 Celsius (oC)
  • AC-DC-AC Converter
  • 50 or 60 Hertz (HZ)
  • Three Phase
  • 2%
  • over/under voltage protection
  • Steel Plate
  • 50KW
  • 2 phase 240 Volt (V)

50KW USA 240 volt input to 3 phase out 480 volt output converter with outdoor cabinet optional Trade Information

  • Paypal Telegraphic Transfer (T/T) Western Union
  • 3000 Piece Per Month
  • 7 Days
  • Yes
  • Contact us for information regarding our sample policy
  • wooden box with pallet
  • Asia Australia Central America North America South America Eastern Europe Western Europe Middle East Africa
  • All India
  • ISO9001, CE

Product Description

50KW USA 240 volt input to 3 phase  out 480 volt output converter with outdoor cabinet  optional


240 volt input to 3 phase  out 480 volt output converter  Advantages:

1. Easy to repair

Adopted Japanese Mitsubishi IPM intelligent module, Modular and simple structure design, very easy and convenient for maintenance, any fault only need us send you parts for replacement, maintenance is low-skill work   

2. Little fault rate 

It with powerful protection function for short circuit, over load and over temperature which is more safe and reliable. Fault rate < 1%

3. 100% full power stable output 

Inside with full power low frequency isolated transformer, 100% full power output, can work 24hx7, which ensure the AC busbar and DC busbar are completely isolated, the harmonic and interference is very little, constant voltage and constant frequency stable output. And the accuracy of output voltage is very high less than 1%. 

4. High efficiency  

> 92%

5. Long service life 

> 15 years

6. Setting flexible

The output frequency 50Hz/60Hz can be set. 

The output voltage can be set. 

7. Two kinds of start mode

Variable Frequency Start or Step Down Voltage Start

With higher capacity to drive motor inductive load, save the cost of soft starter

8. Big LCD display

Display real time running parameters, easy operation


120/240V 60Hz Split phase to 380V 50hz 3 phase converter Specifications:

AC Input

  • AC input voltage - 2 Phase 120/240Vac(L1,L2-N 120V. L1-L2 240V)

    AC Output

    • AC output power - 3kw-500kw avaliable
    • Pure sine wave
    • 380VAC
    • Three phase L1 + L2 + L3 + N + Earth
    • Frequency 50/60 hz
    • Power Factor: >0.95
    • Inverter efficiency: >94%
    • LCD Display
    • Voltage accuracy - Load balancing<1%, Unbalance <5%
    • THD: linear load, 2%, nonlinear load >3%
    • No load amps: 2% of inverter size depending on DC voltage (1000 watts / DC input voltage = amps)

    Protections

    • Overload 150% for 5 seconds, 120% for 35 seconds
    • Input reverse polarity
    • Under voltage
    • Over voltage
    • Output over current
    • Short circuit
    • Over temperature
    • Fan cooled - Always on
    • Short circuit: no automatic recovery. Restart required
    • <50dB
    • Operating temperature: -25 to 55 Celsius
    • Humidity: 90% non-condensing
Enter Buying Requirement Details